HIGH POWER

AIR COOLED

COIL LOADS

 

 

 

 

The Microsorb load division can offer a novel approach to the constraints imposed where high average power levels exist, but cooling by liquid is not possible.

The coil load employs the fundamental loss of circular waveguide to convert RF energy into heat within the optimum physical shape. The variations of power handling, frequency band and packaging require careful optimisation. Contact factory for early assistance.

Detailed below are typical sizes.

FREQUENCY RANGE

 

WAVEGUIDE SIZE

 
GHz
U.K
I.E.C
E.I.A
PART NO.
POWER HANDLING RANGE

 

7.05 -10.0
WG15
R84
WR112
15-HC-9049
1 kW TO 10 kW
8.20-12.4
WG16
R100
WR90
16-HC-9050
0.9 kW TO 8 kW
10.0-15.0
WG17
R120
WR75
17-HC-9051
0.8 kW TO 6 kW
12.4-18.0
WG18
R140
WR62
18-HC-9052
0.8 kW TO 4 kW
18.0-26.5
WG20
R220
WR42
20-HC-9053
0.7 kW TO 2 kW
21.7-33.0
WG21
R260
WR34
21-HC-9054
0.6 kW TO 1 kW
26.5-40.0
WG22
R320
WR28
22-HC-9055
0.5 kW TO 1 kW

 

Customer to specify:
Flange type Certain types may dictate changes in overall length
Material Copper/Brass or Aluminium
Finish External: Black paint standard
Power handling The standard range illustrated are broad band designs.
Most sizes have other power options available - Consult factory for details

 

* There is an important trade off between performance and cost. Please specify your requirements in detail to obtain an optimum solution. Many high performance models are available and the physical size can also be altered to suit your requirements.

 

BACK HOME