FLEXIBLE & FLEXIBLE/TWISTABLE

 

 

GENERAL SPECIFICATION - ELECTRICAL

WAVEGUIDE SIZE

FREQUENCY RANGE

VSWR

ATTENUATION

dB/m

PEAK POWER

I.E.C. E.I.A. U.K.
GHz

FLEX/

TWIST

FLEX ONLY
MW
R14
WR650
WG6
1.14-1.73
1.10
0.02
0.01
12.50
R22
WR430
WG8
1.70-2.60
1.10
0.04
0.04
5.50
R32
WR284
WG10
2.60-3.95
1.10
0.06
0.06
2.50
R40
WR229
WG11A
3.30-4.90
1.10
0.08
0.08
1.70
R48
WR187
WG12
3.95-5.85
1.10
0.17
0.10
1.50
R58
WR159
WG13
4.90-7.05
1.10
0.20
0.13
0.83
R70
WR137
WG14
5.85-8.20
1.10
0.23
0.17
0.60
R84
WR112
WG15
7.05-10.0
1.10
0.27
0.20
0.38
R100
WR90
WG16
8.20-12.4
1.10
0.35
0.33
0.22
R120
WR75
WG17
10.0-15.0
1.15
0.50
0.45
0.18
R140
WR62
WG18
12.4-18.0
1.15
0.65
0.50
0.13
R220
WR42
WG20
18.0-26.5
1.20
1.15
1.15
0.04
R320
WR28
WG22
26.5-40.0
1.30
2.00
1.65
0.02

 

NOTES

GENERAL

Electrical specification is based on a standard straight waveguide assembly, 600 mm long, silver plated brass core stock, plain (cover) flanges, jacketed with silicone rubber. Please contact factory for guidance on your specific requirement. VSWR figure on WG20 and WG22 are for 300 mm lengths.

FREQUENCY RANGE

Most waveguides can be successfully used over extended frequency ranges. They can also be offered with improved electrical performance over reduced parts of band.

ATTENUATION

Figures shown are indicated values, again they may be improved upon reducing frequency range. Lower figures are subject to test equipment limitations due to extreme low levels.

PEAK POWER

Figures quoted assume dry air, at ground level. Consult factory to discuss trade off between peak, average power, temperature, etc.

GENERAL SPECIFICATION - MECHANICAL

PRESSURE

 

OUTSIDE DIMENSIONS

FLEXIBLE/TWISTABLE

TWIST BEND RADII

FLEXIBLE ONLY

BEND RADII

 

SIZE

kPa
psi
mm
±º/m
E mm
H mm
E mm
H mm
I.E.C.
35
5
190x110
20
520
1,025
340
700
R14
35
5
126x70
20
390
645
252
520
R22
50
7
91x53
33
184
248
21
265
R32
50
7
73x44
130
171
210
82
135
R40
60
8.7
59x33
140
116
170
76
106
R48
60
8.7
50x30
195
106
158
70
100
R58
65
9.4
46x27
215
65
90
62
87
R70
70
10
38x21
245
62
87
62
87
R84
70
10
32x18
275
48
67
55
80
R100
105
15
27x17
275
32
60
29
58
R120
105
15
24x17
275
28
51
35
51
R140
138
20
17x10
275
25
34
25
34
R220
138
20
14x10
275
25
31
22
31
R320

NOTES

 

PRESSURE

Safe operating pressure with no degradation of electrical performance. Higher pressures for purging etc., will not damage assemblies but consult the factory for advice. Design features can be incorporated to strengthen assemblies.

BEND RADII.

The figures shown are for static bent condition.

Tighter bend radii can be achieved if required in most applications. Figures shown are minimum radii, to centre line of waveguide. The criteria for minimum bend radii is that which will not significantly degrade electrical performance. Flexible only waveguide is not designed for continuos flexure. Consult the factory for guidance.

ENVIRONMENTAL

Operating temperature range: -50ºC to +180ºC.

 

PREFORM SHAPES

Any twistable or non twistable flexible waveguide can be supplied moulded into a predetermined shape. Consult factory for limitations.

 

Back Home